How to Connect an Alarm Output Device to a Uniview NVR?

Endret Fri, 23 Aug ved 3:24 PM


How to Connect an Alarm Output Device to a

Uniview NVR?

Une image contenant logo, Police, Graphique, symbole

Description générée automatiquement

 

 

Step 1 :

Please refer to the picture below to connect the alarm output device (AC load in the picture).

 

Une image contenant diagramme, texte, capture d’écran, Police

Description générée automatiquement

 

Step 2 :

Log into the NVR’s web interface and set up the alarm output parameters under

Setup>Alarm>Alarm Output.

Une image contenant texte, capture d’écran, nombre, Police

Description générée automatiquement

 

Alarm Output No.: the alarm output port you are trying to configure. 

A->1 refers to the NVR’s Alarm Output Port 1, 

A->2 refers to the NVR’s Alarm Output Port 2, etc. 

D1->1 refers to the D1 camera’s Alarm Output Port 1, 

D3->2 refers to the D3 camera’s Alarm Output Port 2, etc.

Default Status:

N.O. : Normally Open.

N.C. : Normally Closed.

This needs to be set according to the attributes of the external alarm device.


Step 3 

 

Click Trigger under Setup>Alarm>Manual>Manual Alarm to test and see if the alarm output device can be triggered.

 

Une image contenant texte, capture d’écran, logiciel, Icône d’ordinateur

Description générée automatiquement

 


Var denne artikkelen nyttig?

Så bra!

Takk for din tilbakemelding

Beklager at vi ikke kunne være mer til hjelp

Takk for din tilbakemelding

Fortell oss hvordan vi kan forbedre denne artikkelen.

Velg minst én av grunnene
CAPTCHA-verifisering er obligatorisk.

Tilbakemeldingen er sendt inn

Vi setter pris på tilbakemeldingen din og vil prøve å rette på artikkelen