Step 1 :

Please refer to the picture below to connect the alarm output device (AC load in the picture).

 

Une image contenant diagramme, texte, capture d’écran, Police

Description générée automatiquement

 

Step 2 :

Log into the NVR’s web interface and set up the alarm output parameters under

Setup>Alarm>Alarm Output.

Une image contenant texte, capture d’écran, nombre, Police

Description générée automatiquement

 

Alarm Output No.: the alarm output port you are trying to configure. 

A->1 refers to the NVR’s Alarm Output Port 1, 

A->2 refers to the NVR’s Alarm Output Port 2, etc. 

D1->1 refers to the D1 camera’s Alarm Output Port 1, 

D3->2 refers to the D3 camera’s Alarm Output Port 2, etc.

Default Status:

N.O. : Normally Open.

N.C. : Normally Closed.

This needs to be set according to the attributes of the external alarm device.


Step 3 

 

Click Trigger under Setup>Alarm>Manual>Manual Alarm to test and see if the alarm output device can be triggered.

 

Une image contenant texte, capture d’écran, logiciel, Icône d’ordinateur

Description générée automatiquement

 


Archivos adjuntos (1)

¿Le ha sido útil este artículo?

¡Qué bien!

Gracias por sus comentarios

¡Sentimos mucho no haber sido de ayuda!

Gracias por sus comentarios

¡Háganos saber cómo podemos mejorar este artículo!

Seleccione al menos una de las razones
Se requiere la verificación del CAPTCHA.

Sus comentarios se han enviado

Agradecemos su esfuerzo e intentaremos corregir el artículo