Step 1 :
Please refer to the picture below to connect the alarm output device (AC load in the picture).
Step 2 :
Log into the NVR’s web interface and set up the alarm output parameters under
Setup>Alarm>Alarm Output.
Alarm Output No.: the alarm output port you are trying to configure.
A->1 refers to the NVR’s Alarm Output Port 1,
A->2 refers to the NVR’s Alarm Output Port 2, etc.
D1->1 refers to the D1 camera’s Alarm Output Port 1,
D3->2 refers to the D3 camera’s Alarm Output Port 2, etc.
Default Status:
N.O. : Normally Open.
N.C. : Normally Closed.
This needs to be set according to the attributes of the external alarm device.
Step 3
Click Trigger under Setup>Alarm>Manual>Manual Alarm to test and see if the alarm output device can be triggered.