SW1 to erase memory of the control unit :
- Power off the control Unit.
- Hold SW1 Swtich while restoring Power.
- Wait for the blue LED on the expansion bus to light up (approximately 10 seconds) while holding the switch down.
- Release SW1
SW2 to restore factory network settings (IP address : 192.168.2.150, mask 255.255.255.0).
- Power off the control Unit.
- Keep the switch pressed while turning the power back on.
Remark :
- To configure the control unit with a fixed IP address, release the switch at the first flash of the extension bus LED (about 5 seconds).
- To configure the control unit in DHCP mode, wait for the second flash of the extension bus LED (approximately 5 seconds after the first flash).
- Release SW2
¿Le ha sido útil este artículo?
¡Qué bien!
Gracias por sus comentarios
¡Sentimos mucho no haber sido de ayuda!
Gracias por sus comentarios
Sus comentarios se han enviado
Agradecemos su esfuerzo e intentaremos corregir el artículo