ACS change of configuration method

Modificato il Mar, 4 Nov alle 12:04 PM

 

When you configure the control panel using one of the methods (GGM ACS or ACS Web), it becomes locked to that method and you can no longer switch configuration modes.

For example, if the panel was configured via GGM ACS, you will no longer be able to configure it via ACS Web — it will remain locked to GGM ACS, and vice versa.

If you still want to change the configuration method, you must reset the panel.



SW1 to erase memory of the control unit :

- Power off the control Unit.

- Hold SW1 Swtich while restoring Power.

- Wait for the blue LED on the expansion bus to light up (approximately 10 seconds) while holding the switch down.

- Release SW1



Once the panel has been reset, you will be able to choose between the two configuration methods again.

Please find below the link to the reset procedures:

Access Control : How to RESET control unit with SW1 & SW2 buttons ?

Questa risposta ti è stata utile?

Fantastico!

Grazie per il tuo feedback

Siamo spiacenti di non poterti essere di aiuto

Grazie per il tuo feedback

Facci sapere come possiamo migliorare questo articolo!

Seleziona almeno uno dei motivi
La verifica CAPTCHA è richiesta.

Feedback inviato

Apprezziamo il tuo sforzo e cercheremo di correggere l’articolo