How to Connect an Alarm Input Device to a Uniview NVR?

Ändrad den Fre, 23 aug. vid 3:13 E.M.

How to Connect an Alarm Input Device to a

Uniview NVR?

Une image contenant logo, Police, Graphique, symbole

Description générée automatiquement

Step 1 Cable connection

The positive pole/Signal wire of the alarm input device is connected to the ALM IN port on the NVR. The negative pole/Ground wire of the alarm input device is connected to the G port on the NVR

 

Une image contenant diagramme, texte, capture d’écran, Police

Description générée automatiquement

 

 

Step 2 :

Set up input parameters of the alarm under Setup> Alarm>Alarm Input on the NVR’s web interface.

Une image contenant texte, logiciel, Icône d’ordinateur, Page web

Description générée automatiquement

 

Alarm Input No.: the alarm input port you are trying to configure. 

A<-1 refers to the NVR’s Alarm Input Port 1, 

A<-2 refers to the NVR’s Alarm Input Port 2, etc.

D1<-1 refers to the D1 camera’s Alarm Input Port 1, 

D3<-2 refers to the D3 camera’s Alarm Input Port 2,

Alarm Input Name: Set a name for it as you wish.

Alarm Type

- N.O. : Normally Open.

- N.C. : Normally Closed.

This needs to be set according to the attributes of the external alarm device.

Alarm Input: Switch to turn this alarm input on or off

Var artikeln till hjälp?

Toppen!

Tack för din feedback

Vi beklagar att det inte var till hjälp

Tack för din feedback

Berätta för oss hur vi kan förbättra den här artikeln!

Välj minst en av orsakerna
CAPTCHA-verifiering krävs.

Feddback skickat

Vi uppskattar din feedback och uppdaterar artikeln vid behov